Monday, May 24, 2010

Hyundai Getz(TB) Impossible to Shift ATM(3rd Hold)=pulse Generator B

Model: Getz Year model: 2004 Mileage:78524km
Displacement: 1500cc Fuel: Gasoline T/A :Auto
N code:Impossible to shift(3rd hold) C code: Flaw in material System: Automatic trans. Control System
Subject: Impossible to shift ATM hold to 3rd = pulse Generator


1)  Trouble Condition:

  1. Impossible to shift auto transmission(3rd hold).
  2. Shock occurence when shifting gear N—>D,N—>R.

2) Trouble Cause:

  • Poor pulse Generator(B).

3) Trouble Diagnosis: 

  1. Scan tool check
    = Diagnostic Trouble code.
                                            DTC code
        P0722 Pulse Generator B (output Speed Sensor)
  • = Perform a driving test after erasing the DTC code.
  • = The DTC code is Displayed again.

     2   Inspect the oil in Auto transmission – Normal.

         = Transaxle fluid: Genuine Diamond ATF SP-III

     3   Stall test = Normal .
          = Stall speed: 2200 – 2800 rpm
          = Place the selector lever in the “R” position.
     4   Inspect the resistance in pulse generator and wiring contact.

4) Trouble Repair Guide:

  1. Normal current data G scan of pulse Generator of A & B
    =
    PG-A(Input speed)      1532 rpm
    = PG-B(output speed)     968 rpm
  2. Pulse Generator circuit.
  3. Measure the resistance of output sensor
    = Channel 1 prove (+): Input sensor C02 terminal 4 signal line.
    = Channel 1 prove (-): Input sensor C02 terminal 3 sensor ground.
    =Specification: 245 + or – 30 ohms(Standard 20*c

C02 Terminal.

  1. Input speed sensor (+)
  2. Input speed sensor (-)
  3. Output speed sensor (+)
  4. Output speed sensor (-)